The leading manufacturer of heatsinks, thermal conductive materials, cases and connectors.
Service hotline
MON-THR 7:30 - 15:45
FRI 7:30 - 15:15
E-mail service

Cooling aggregates

25 - 36 (111)Number:
la25.tif
160 x 83 mm, with radial fan
lagi40_.eps
for fanmotor 40x40mm
la10.tif
160 x 83 mm, with axial fan
la11.tif
240 x 83 mm, with axial fan
la_v9.tif
80 x 83 mm, with axial fan and air-flow chamber
la_v10.tif
160 x 83 mm, with axial fan and air-flow chamber
la_v11.tif
240 x 83 mm, with axial fan and air-flow chamber
la_31.tif
85 x 85 mm, with axial fan
High performance cooling aggregate
  • compact construction by means of connected extruded profiles
  • excellent efficiency by means of flow-optimised hollow fin structure
  • powerful axial fans
  • double-sided precise milled semiconductor mounting surfaces
  • different width dimensions, customised machinings, surfaces, fan types and fan voltages upon request
la_32.tif
164,6 x 85 mm, with axial fan
la_33.tif
244,2 x 85 mm, with axial fan
la_v31.tif
85 x 85 mm, with axial fan and air-flow chamber
High performance cooling aggregate
  • additional efficiency enhancement and noise reduction by means of air-technically adjusted airflow chambers
  • excellent thermal efficiency in connection with powerful axial fans
  • double-sided precise milled semiconductor mounting surfaces
  • different width dimensions, customised machinings, surfaces, fan types and fan voltages upon request
la_v32.tif
164,6 x 85 mm, with axial fan and air-flow chamber
25 - 36 (111)Number:
The increasing construction of big load circuits for drives and controls lead to a use of always bigger and more powerful electronic devices such as IGBT and similar. In those power classes a heat dissipation is only possible by forced convection by means of cooling aggregates or fluid heatsinks. A cooling aggregate consists of an assembly of fins, lamellas or similar, suitable geometries for heat exchanging surfaces and one or more fans. The electric devices mounted on the cooling aggregate bring the developed dissipation loss as a thermal output into the construct cooling aggregate by means of heat conduction. The existing fan produces an air flow which is navigated to the internal structure in a cooling aggregate and dissipates the inserted heat to the outside. Different conceptions for a cooling aggregate are the high capacity-, segment- and miniature cooling aggregates with different structures of the heat exchanging surfaces which are equipped with axial-, diagonal or radial fans in dependence to the overall conception. The offered concepts from Fischer Elektronik are based on the cooling aggregate itself and the resulting versatile modification possibilities in size, design and type of fan.

Cookies